www.jlblosser.com/  
  JLB_Logo
Resiment   Ready-Mix Dual Cure  
 
  Resiment Resin Cement    
     
 
Resiment® Resin Cement
Product Information
Resiment Standard BIS-GMA self-curing resin cement
Resiment Fluoride. BIS-GMA self-curing resin cement with Fluoride
 

Resiment Standard and Resiment Fluoride are permanent BIS-GMA self-curing resin cements for your cementation needs. Resiment Cements can be used for the final cementation of crowns, bridges, implant prosthesis, inlays and onlays, Maryland bridges, pins and posts.

Resiment is designed to be easy to use and cost effective for your office.

 

Resiment Std and FL

Why Use Resiment

  • Resiment is an auto-curing, filled, multi-purpose cement.
  • It can be used for final cementation of Implant Prostheses, Bridges, Crowns, Inlays, Maryland Bridges, Cementation of Pins, Posts, Pit and Fissure Sealant and Periodontal Splinting.
  • Great for short clinical crowns.
  • Can be used on Dentin, Enamel, Composite, or Metal.
  • Available in fluoride releasing and standard formulas
  • Resiment is the cement of choice for many implant clinicians and is recommended by implant companies
 
Specifications
Tensile strength
Compressive strength
Film thickness
pH
Water solubility
Radiopaque
41 MPa (5,920 psi)
208 MPa (30,135 psi)
45 µ
7
0.07
Yes
 

Working and Setting Time
Working Time is approximately 1 minutes at 22 degrees C / 72 degrees F Room Temperature.
Final Setting Time is approximately 3 minutes at 37 degrees C / 98 degrees F Body Temperature.

Warm intraoral environment will accelerate working and setting times.  The cement will set quickly when it comes in contact with primers on the tooth

Presentation

Resiment Resin Cement Standard and Resiment Resin Cement Fluoride are presented in a Kit format. Each kit contains:

  • 1 syringe containing 5 grams of base
  • 1 syringe containing 5 grams of catalyst
  • 1 mixing pad
  • 2 mixing spatulas

Specify formulation and delivery system when ordering

 
Item Description
MSRP US $
*
RES 2-STD
Resiment Standard
$ 124.95
 
RES 2-FL Resiment Fluoride
$ 128.60
 
RMP-50 Resiment Mixing Pad 3 X 3 (Pad of 50)
$ 3.15
 
Technical Information
Directions For Use
 

Ceramic Restorations To Teeth

  • After try-in, place etched ceramic restoration in acetone or ethanol in ultrasonic cleaner for 1-2 minutes.
  • Place silane coupling agent on internal surface of porcelain restoration.
  • Clean tooth with non-fluoridated prophy paste or flour of pumice.
  • Use enamel and dentin bonding system of your choice to prepare tooth for bonding.
  • After mixing equal amounts of catalyst and base for 15-30 seconds and place into restoration.
  • Seat restoration in place on tooth and hold in place until Resiment reaches initial set. (Approx. 1.5 minutes.)
  • Remove excess cement IMMEDIATELY after initial set. Using explorer, scaler, or brush check for rubbery consistency. Clean excess when cement gets to rubbery stage. Do not wait until final set (3.5 minutes).

Metal To Metal

Metal to metal restorations (implant prosthesis or crown on post)

  • Use an air abrasive system (sandblasting) on all external metal surfaces to be exposed to Resiment. Intraoral metal should be roughened by a bur or a micro-etcher.
  • If desired, apply a metal priming system of your choice to treat the metal exposed to Resiment.
  • Clean posts or abutments with non-fluoridated pumice prior to cementation to remove any debris from the surface.
  • Mix equal amounts of Resiment base and catalyst for 15-30 seconds and place into restoration.
  • Seat restoration in place on tooth and hold in place until Resiment reaches initial set. (Approx. 1.5 minutes)
  • Remove excess cement IMMEDIATELY after initial set. Using explorer, scaler, or brush to check for rubbery consistency. Clean excess when cement gets to rubbery stage. Do not wait until final set (3.5 minutes) to remove.

STORAGE:  Store at room temperature (20ºC/68ºF-25ºC/77ºF).

PRECAUTIONS: Uncured resins may cause skin sensitizations in susceptible persons. In case of contact, wash skin with soap and water.

WARRANTY: J.L. Blosser, Inc. recognizes its responsibility to replace products if proven to be defective. J.L. Blosser, Inc. does not accept liability for any damage or loss, either direct or consequential, stemming from the use or inability to use the products as described. Before using, it is the responsibility of the user to determine the suitability of the product for its intended use. The user assumes all risk and liability in connection therewith.

CAUTION: U.S. Federal Law restricts this device to sale by or on the order of a dental professional.

 
Addition information and answers to Frequently Asked Questions are available here
 
Certifications
FDA
CE
Health Canada
 
 
Material Safety Data Sheets (MSDS)
 
The current Material Safety Data Sheets for Resiment Standard and Resiment Fluoride are available here
 
Links to additional resources on jlblosser.com
*Prices subject to change without notice.
Registered Trademarks(®) and Trademarks (™)
Resiment and Ready-Mix are registered trademarks of J.L. Blosser Inc.
 
J.L. Blosser Inc.-- 22 North Main St., Liberty, Missouri USA 64068 -- 816-781-3206 -- 800-200-3594 -- fax 816-781-0164